source:Industry News release time:2022-03-26 Hits: Popular:Brand bar audio wholesale

The power sequencer can start the power supply one by one from the front-end equipment to the latter-level equipment, and when the power supply is closed, it can close all kinds of electrical equipment in the order from the latter-level to the previous-level, so that it can effectively manage and control all kinds of power. The electrical equipment avoids human error operation, and at the same time, it can reduce the impact of the electrical equipment on the power supply grid at the moment of switching, and also avoid the impact of the induced current on the equipment, ensuring the stability of the entire power system.
Selection of power sequencer
The stability of the voltage is ranked first. I think we have no opinion. The stable operation of the sequencer is a reliable condition of the system. The sequencer often does not turn on, or one or two channels are not turned on from time to time. No matter how good the system is, it is useless. In addition to its reliable operation, it also needs to have a certain anti-interference ability. Part of the disturbance source of the timing shock comes from the power supply external network. This part of the disturbance mainly includes surges and pulse peaks generated by induction lightning, motors, fluorescent lamps, etc.; the other part is When the system starts, the internal power supply of the device is charged or the disturbance caused by the switching power supply.
1. Power on the sequencer first, set the sequencer interval time to 1 second, then start the sequencer to start the function, switch on and off the fluorescent lamp or electric drill in the room during the start-up process, pay attention that the sequencer cannot be restarted or there is a channel that is not open In this case, this method has to be tested several times. If possible, use the pulse generator to inject disturbance pulses into the mains supply (220V power) of the sequencer, and add the disturbance intensity in stages during the test to test the anti-disturbance intensity of the sequencer under test. Generally speaking, it should reach 1KV ( 1000V) and above.
2. Connect a load (preferably a high-power amplifier) to each output of the sequencer. If there is not that much load, you can connect the load to the last few consecutive circuits (such as CH12, 11, 10, 9). Then power on the sequencer and start the sequence start function (note that if the timing interval is adjustable, the interval should be adjusted to 1 second). During the start-up process, the sequencer cannot be restarted or the channel cannot be opened.
3. Capacity
The overall current demand of the system is the standard for selecting the capacity of the sequencer. There are 20A, 30A, 40A, and 50A current options in the market; the capacity of a single channel is generally 10A or 13A; now some manufacturers use 30A relays, The output current is 30A, but the output socket uses an American or universal socket. The rated current of this socket is 10A, and some thickened shrapnel is 13A. It can be seen from this that the output current cannot reach 30A. You can test the RCF audio with a load of 30A; during the test, use a load with a current of 10A, connect it to the nominal total capacity current, and boil water for 4 hours. The surface temperature of the power lead should not exceed 60 degrees, and it should not be hot to the touch; the sequencer should not emit a mushy smell.
4. Extensible
The number of output channels of the power sequencer is divided into 4 channels, 8 channels, 10 channels, 12 channels, etc. When the number of devices exceeds the number of one sequencer channel, it is necessary to expand (cascade) use, and pay attention to expansion when selecting Afterwards, it can be opened from the first road to the Z rear road, and can also be closed from the Z rear all the way to the first road.
5. Function
Select according to project requirements, such as level start function, DC-2208, DSP-480, TCP/IP control function, status monitoring; timing interval, normally open configuration function; power purification, anti-surge, voltage, current monitoring and protection functions, etc. .
Popular recommendation
F124 Home ktv audio Vendor
2021-07-14I3 Small bar sound Vendor
2021-07-26F88 Car stereo Merchant
2021-07-16F81 Bar speaker company
2021-07-16XD10 KTV audio manufacturer
2021-07-26D80DSP Large bar sound Vendor
2021-07-26Resolution 1 Bar ktv sound Vendor
2021-07-16Bass Reflex Range Bar hall sound Vendor
2021-07-14MB210 Low Profile Bar audio set Merchant
2021-07-14F55 Bar speaker company
2021-07-16EVO 7THBar sound company
2021-07-17XD18I Bar speakers wholesale
2021-07-26Bar Audio System FUNKTION ONE Mateng Audio
2022-12-23Dongguan Party Master Professional Audio recommends Mateng Audio
2022-01-13Acoustic sound sensor
2022-10-20Analysis of common problems in the use of video conferencing systems
2022-09-05The role of sound.Marten Audio Vendor
2021-12-11What are the main stage audio equipment and what are they!Marten Audio Vendor
2021-11-01application of audio line array audio in various complex audio environments and bar project cases
2021-09-17Sound characteristics of countries all over the world.Changde Bar Speaker Vendor
2021-12-02What preparations should be made before using professional audio equiConference room sound promotion
2022-06-21What are the new markets for professional audio?
2022-10-13Take you to understand the maintenance of KTV professional audio equipment!Speaker bar Vendor
2021-10-21How to avoid failure of each component in the stage audio supporting system
2022-05-09