Professional audio systems are composed of many different functional devices. After designing the audio system according to the use requirements and selecting the equipment used, these discrete devices should be connected according to the design requirements to form a complete set of audio systems that can achieve the design requirements. For a fixed installation system, the equipment should be installed in a cabinet, and all system connections should be fixedly installed in accordance with certain standards and specifications. For mobile systems, such as temporary installations such as concerts and outdoor performances, effective temporary fixing measures should be taken for equipment and cables to ensure their safety.
The connection and installation of the audio system involves many engineering issues, including the design and construction of the audio control room, the pipeline engineering of the audio system cable, and the power supply of the system. Here are some issues that need to be paid attention to in the transmission of audio system signals.
1. Impedance matching
The signal input port is also the load of the signal output port, and the impedance matching between them needs to be within the range to meet its requirements, which generally depends on the design requirements of the signal output device. In order to achieve the best transmission state of the audio electrical signal, the impedance of the signal input interface must meet the impedance matching requirements of the signal source output interface to its load, otherwise, it will affect the working state of the audio equipment and cause distortion of its output signal. In severe cases, there is even a risk of damaging the audio source equipment.
Theoretically, when the output impedance is equal to its load impedance, the transmission efficiency of the signal is the highest. However, if the output impedance is greater than the load impedance, most of the signal power will be lost on the signal output circuit, which is obviously not conducive to signal transmission. Therefore, audio equipment is usually designed so that the input impedance is greater than the output impedance.
The connection of general audio equipment, as long as the load impedance is greater than the impedance of the signal output end, can make it work normally. However, the input impedance of the audio equipment cannot be designed to be too high or too low. If it is too high, it will reduce the anti-interference of its feeder. If it is too low, it will cause its frequency response index to decrease.
2. Signal transmission level
The purpose of the audio system connection is to transmit signals. The optimal state of audio signal transmission requires that the level value output by the signal source must be greater than or equal to the sensitivity of the input interface. Otherwise, the signal-to-noise ratio index of the signal will deteriorate. The gain of the line input and output circuits on professional audio equipment is generally set at 0dB, that is to say, the equipment neither amplifies nor attenuates the level of the input or output signal, so that it can be maintained during the transmission process. Its level value remains unchanged, which is mainly to ensure that the adjustment of the level control unit can be numerically guaranteed.
In the system connection, attention should be paid to the matching of output and input levels. Otherwise, clipping distortion may be caused, or the excitation signal may be insufficient, resulting in a decrease in the signal-to-noise ratio of the entire system. Usually the connections between audio equipment (mixers, peripherals, amplifiers) are at line level to transmit signals. There are generally two line standards, one is +4dB (1.228V), and the other is 0dB (0.775V). The line level of the equipment used in the system should be unified, so that it will be more convenient to adjust and use. In addition, some sound processing equipment, especially the effector, in order to take into account the needs of electro-acoustic musical instruments and professional sound systems, the interface level conversion function is set. -10dB, -20dB several gears, when using the sound reinforcement system, you should pay attention to adjust it to +4dB gear.
Popular recommendation
Resolution 2 School audio company
2021-07-15C12 Bar hall sound Merchant
2021-07-26F315 Mini bar sound Vendor
2021-07-14Resolution 18 Bar speaker Vendor
2021-07-17A3 Home ktv audio Merchant
2021-07-26XQ48 Bar sound bar Merchant
2021-07-26AX 88KTV audio sales
2021-07-17F81 Bar speaker company
2021-07-16Resolution 4S Skeletal Bar use audio Vendor
2021-07-16I8SUB Gymnasium audio Vendor
2021-07-26F215 MK2 ktv bar sound Factory
2021-07-14XD18I Bar speakers wholesale
2021-07-26Electronic music sound system Finland AURA AUDIO China entertainment general agent Mateng Audio
2021-12-09What are the parts of the sound.Bar speakers sales
2022-04-27Performance index of loudspeakers!Bar bar sound Processing
2022-11-14What are the precautions when using conference speakers?
2021-09-07The choice of karaoke karaoke machine.Bar hall sound Vendor
2021-11-15These are just the basics! Explanation of common terms used by sound engineers
2022-04-21What should I do if the sound of the speaker is hoarse?
2021-12-18Pressure Limit Control in Professional Audio System
2022-08-05Electronic music audio Finland AURA AUDIO
2021-12-23Stage sound is an important branch of performance equipment!Sound for bars Vendor
2021-11-04Is the effect of conference sound engineering good?Speakers for bars Vendor
2021-11-27What is the general audio used in the electric bar? Mateng Audio
2023-01-04